MPH
- Head
Aluminium: MPH 110-114-116-120-250
Anodized Aluminium: MPH 630-850
Painted Aluminium: MPH 660
- Cover
Polyamide: MPH 110-114-116-120
Aluminium: MPH 250
Anodized Aluminium: MPH 630
Painted Aluminium: MPH 660
Steel: MPH 850
- Insert assembly
Polyamide: MPH 110-114-116-120
Aluminium: MPH 250-630-660-850
- Diffuser: Stainless Steel
- Valve: Phosphatized Steel
Filter housing materials
- Opening pressure 175 kPa (1.75 bar)±10%
- Opening pressure 250 kPa (2.5 bar) ±10%, except for MPH 850
Bypass valve
From -25 °C to +110 °C
Temperature
- Microbre lter elements - series MR: 10 bar
- Fluid ow through the lter element from IN to OUT
∆p element type
- Standard NBR series A
- Optional FPM series V
Seals
MPH lters are provided
for vertical mounting
Note
Maximum working pressure up to 1 MPa (10 bar)
Flow rate up to 3500 l/min
GENERAL INFORMATION
Description Technical data
Return lter
MPH is a range of return lters for protection of the reservoir against
the system contamination.
They are directly xed to the reservoir, in immersed or semi-immersed
position.
The use of the diffuser is recommended, to place the lter output
always immersed into the uid to avoid aeration or foam generation
into the reservoir.
The filtration from inside to outside allows a cleaner filter element
replacement, the dirty remains into the lter element.
Available features:
- Female threaded connections up to 1 1/2” and anged connections
up to 4”, for a maximum ow rate of 3500 l/min
- Multiple connections, to connect several return lines or drains
- Fine ltration rating, to get a good cleanliness level into the reservoir
- Bypass valve, to relieve excessive pressure drop across the lter media
- Magnetic lter, to hold the ferrous particles
- 2, 3, 4 or 8 xing holes for installation, to suit a variety of reservoir
surfaces
- Flat Seal to suit a variety of reservoir surfaces
- Oil dipstick, to easily check the level of the fluid into the reservoir
(separate item)
- Diffuser, to reduce the risk of aeration, foaming and noise
- Filler plug, to ll cleaned uid into the tank without an additional plug
- Integrated breather lter, to clean the air that moves into the reservoir
as result of the oil level uctuation (MPH110/114)
- Integrated breather filter with pressurization valve, to clean the air
that moves into the reservoir as result of the oil level uctuation and to
guarantee the pressurization into the reservoir (MPH110/114)
- Visual, electrical and electronic clogging indicators
Common applications:
Heavy duty industrial equipment
Weights [kg] and volumes [dm
3
]
1.60 1.70 1.80 2.20 2.60
1.60 1.70 1.80 2.20 2.60
1.60 1.70 1.80 2.20 2.60
1.60 1.70 1.80 2.20 2.60
3.60 3.90 4.20 5.60 -
6.50 7.00 7.40 8.50 10.50
- - - 11.50 14.00
32.00 35.00 38.00 42.00 -
1 2 3 4 5
1.60 1.70 1.80 2.20 2.60
1.60 1.70 1.80 2.20 2.60
1.60 1.70 1.80 2.20 2.60
1.60 1.70 1.80 2.20 2.60
4.40 4.40 5.40 8.00 -
7.30 9.00 11.00 13.00 19.20
- - - 14.60 21.00
13.00 16.50 21.00 25.00 -
1 2 3 4 5Length Length
Weights [kg]
MPH 110
MPH 114
MPH 116
MPH 120
MPH 250
MPH 630
MPH 660
MPH 850
Volumes [dm
3
]
Filter series
Return lters
210